ELECTRICITY MEASURING METER DT-830B

GENERAL

      
M83 instruments are a series of compact pocket-sized 3 1/2digit multi-meters for measuring DC and AC voltages, DC current, resistance and diode. Some also provide temperature; transistor measurement and audible continuity test function or can be used as a signal generator. Full range overload protection and low battery voltage indicator are also provided. They are ideal instruments for use in the fields, such as in laboratories, workshops, as well as for hobbies and home applications.

FRONT PANEL DESCRIPTION

1.
FUNCTION AND RANGE SWITCH
      This switch is used to select the function and desired range as well as to turn on the instrument.
      To extend the life of the life of this battery, the switch should be in the "OFF" position when the instrument is not being used.
2.
DISPLAY
3 1/2 digit, 7 segment, 0.5" high LCD.
3.
"Common" JACK
Plug in connector for black (negative) test lead.
4.
"V-Ohm mA Cx" JACK
Plug in connector for red (Positive) test lead for 10A measurement.

SPECIFICATION

Accuracy are guaranteed for 1 year, 23°C ± 5°C, less than 75 % RH

DC VOLTAGE

RANGE RESOLUTION ACCURACY
 
200mV 0.1mv ± 0.25% of rdg ± 2D
200mV 1mv ± 0.5% of rdg ± 2D
20V 10mv ± 0.5% of rdg ± 2D
200V 100mv ± 0.5% of rdg ± 2D
1000V 1v ± 0.5% of rdg ± 2D

OVERLOAD PROTECTION: 220 V rms AC for 200mV range and 1000V DC or 750 Vrms AC for other ranges.


AC VOLTAGE

RANGE RESOLUTION ACCURACY
 
200V 100mv ± 1.2% of rdg ± 10D
750V 1v ± 1.2% of rdg ± 10D

OVERLOAD PROTECTION: 1000V DC or 750 Vrms for all ranges. RESPONSE: Average responding, calidrated in rms of a sine waye.


FREQYENCY RANGE: 45Hz-450Hz

DC CURRENT

RANGE RESOLUTION ACCURACY
     
0.2mA 100nA ± 1% of rdg ± 2D
2mA 1000nA ± 1% of rdg ± 2D
20mA 0.01mA ± 1% of rdg ± 2D
200mA 100mA ± 1.2% of rdg ± 2D
10A 10mA ± 2% of rdg ± 2D

OVERLOAD PROTECTION: 200mA 250V fuse (10A range unfazed.)
MEASURING VOLTAGE DROP: 200Mv

RESISTANCE

RANGE RESOLUTION ACCURACY
     
200 ohm 100m ohm ± 0.8% of rdg ± 2D
2k ohm 1 ohm ± 0.8% of rdg ± 2D
20k ohm 10 ohm ± 0.8% of rdg ± 2D
200k ohm 100 ohm ± 0.8% of rdg ± 2D
2000k ohm 1k ohm ± 1% of rdg ± 2D

MAXIMUM OPEN CIRCUIT VOLTAGE: 2.8v.
OVERLOAD PROTECTION: 15 seconds maximum 220 Vrms. Sounds alarm.


AUDIBLE CONTINUITY

·))) built- in buzzer sounds if resistance is less then 100 ohm
OVERLOAD PROTECTION: 15 seconds maximum 220 Vrms. Sounds alarm.

TEMPERATURE (K TYPE PROBE)

RANGE RESOLUTION ACCURACY
     
-20°C to 1370°C 1°C ± 3 ± 2D (up to 150°C)
± 3 of rdg (over 150°C)
OVERLOAD PROTECTION: 220vrms AC.

OPERATING INSTRUCTIONS

WARNING

1.
To avoid electrical shock hazard and/or damage of the instrument, do not measure voltage that might exceed 500V above earth ground.
2.
Before the use of the instrument, inspect test leads, connectors and probes for cracks, breaks, or crazes in the insulation.

DC VOLTAGE MEASUREMENT

1.
Connect red test lead to "V W mA" jack; black lead to "COM" jack.
2.
Set RANGE switch to desired DCV position, If the voltage to be measured is not known beforehand, set switch to the highest range and reduce it until satisfactory reading is obtained.
3.
Connect test lead to device or circuit being measured.
4.
Turn on power of the device or circuit being measured, voltagevalue on Digital Display along with the voltage polarity.

AC VOLTAGE MEASUREMENT

1.
Red lead to "V Ohm mA" Black lead to "COM"
2.
RANGE switch to desired ACV position.
3.
Connect test leads to device or circuit being tested.
4.
Read voltage value on Digital Display.

DC CURRENT MEASUREMENT

1.
Red lead to "V W mA." Block lead to "COM" (For measurements between 200mA and 10A connect red lead to "10A" jack with fully depressed.)
2.
RANGE switch to desired DCA position.
3.
Open the circuit to be measured, and connect test leads.

RESISTANCE MEASUREMENT

1.
Red lead to "V Ohm mA." Black lead to "COM."
2.
RANGE switch to desired Ohm position.
3.
If the resistance being measured is connected to a circuit, turn off power and discharge all capacitors before, measurement.
4.
Connect test leads to circuit being measured.
5.
Read resistance value on Digital Display.

DIODE MEASUREMENT

1.
Red lead to "V Ohm mA." Black lead to "COM."
2.
RANGE switch to Ohm position.
3.
Connect the red test lead to the anode of the diode to be measured and black test to cathode.
4.
The forward voltage drop in mV will be displayed. If the diode is reversed, figure "1" will be shown.

TRANSISTOR hFE MEASUREMENT

1.
RANGE switch to the hFE position
2.
Determine whether the transistor is NPN of PNP type and locate the Emitter, Base and Collector leads. Insert the leads into the proper holes of the the hFE Socket on the front panel
3.
The meter will display the approximate hFE. Value at the condition of base current 10mA and VCE 2.8C

TEMPERATURE MEASUREMENT

1.
Connect the k type thermoelectric couple to "V Ohm mA" and "COM" jacks.
2.
RANGE switch to TEMP position.
3.
The display will read Temperature value °C

ROOM TEMPERATURE MEASUREMENT

       M835 can be used to measure room temperature (0°C to 35 °C) without a thermoelectric couple. Simply set the RANGE switch to RT position and the current room temperature will be displayed.

CAPACITANCE MEASUREMENT

1.
Set the FUNCTION switch to the F range to be used.
2.
Connect the test capacitor to the "V Ohm mA cx" jack and the "COM" jack.

AUDIBLE CONTINUITY TEST

1.
Red lead to "V Ohm mA." Black lead to "COM"
2.
RANGE switch to position.
3.
Connect test leads to two points of circuit to be tested. If the resistance is lower than 100 ohm, buzzer will sound.

TEST SIGNAL USE

1.
RANGE switch to position.
2.
A test signal (50Hz for M832 M835 M837 8301 and1000Hz for m833) appears between to "V Ohm mA" and "COM" jack. The output voltage is approximate 5V p-p with 50 k ohm impedance.

BATTERY AND FUSE REPLACEMENT

    
   
Fuse rarely needs replacement and blows almost always as a result of operator's error.